Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Vane pump common troubleshooting - pump output flow is insufficient or even no oil
1. The motor is not turning properly
2. The tank level is too low
3. Suction line or filter plugged
4. The motor speed is too low
5. Oil viscosity is too large
6. Oil pan end wear
7. Blade on the inner surface of the poor contact
8. Blades stuck in the blade slot or move inflexible
9. Loose connection screw
10. Relief valve failure
Correct the turn
2. Make up the oil line
3. Dredge the suction line, cleaning the filter
4. Turn the speed above the minimum speed of the hydraulic pump
5. Check the quality of oil, replace the viscosity of the hydraulic oil or increase the oil temperature
6. Grind the end or replace the oil pan
7. Grind the contact surface or replace the blade
8. Check one by one, re-deployment of inflexible leaves
9. Tighten properly
10. Adjust, disassemble, clean the relief valve
More keyword search: vane pump
E-mail naar dit bedrijf
January 03, 2024
January 03, 2024
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.