Suzhou Macxi Fluid Technology Co.,Ltd.
Huis> Blog> Tiancheng special pump centrifugal pump adjustment method

Tiancheng special pump centrifugal pump adjustment method

November 05, 2022

Centrifugal pump operating point, is the intersection of pump characteristic curve and pipeline characteristic curve. Artificial changes to the pump operating conditions point method, called the pump regulation. There are only two ways to change the working point of the centrifugal pump: one is to change the pump characteristic curve and the other is to change the pipeline characteristic curve.

(1) change the pump characteristic curve to adjust:

① change speed control pump performance;

② turning impeller diameter, expanding the scope of use;

③ remove the impeller series, multi-stage pump impeller can be removed by the series, to adjust the purpose of head.

(2) to change the pipeline characteristic curve to adjust:

① outlet valve closure regulation;

② by-pass valve to adjust.

【Print】 【Close】
Neem contact op

Author:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

populaire producten
You may also like
Related Categories

E-mail naar dit bedrijf

Onderwerp:
E-mail:
bericht:

Your message must be betwwen 20-8000 characters

Neem contact op

Author:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

populaire producten

Huis

Product

Whatsapp

Over ons

onderzoek

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

verzenden