Suzhou Macxi Fluid Technology Co.,Ltd.
Huis> Blog> How To Add Lubricant To Routine Maintenance Of Merton Wheel Dosing Pumps?

How To Add Lubricant To Routine Maintenance Of Merton Wheel Dosing Pumps?

April 11, 2024
Milton-meter metering pump in the use must pay attention to routine maintenance, and to give the Milton-meter metering pump to add lubricant is a good way of maintenance, then how to add the lubricant is the right way? Xiaobian take a look at it! Bill Milton metering pump routine maintenance How to add lubricants? 1. Lubricants to be replaced after the initial 250 hours of operation. After every 2500 hours or six months to replace the oil. Check the check valve every six months, according to the actual use of the decision whether to replace. When the ambient temperature is below 100C, the winter lubricant (Mobil 626 etc.) should be replaced. MILTONROY dosing pump / dosing pump troubleshooting: 1. Motor overheating: a. Three-phase power phase loss b. Motor wiring is not correct c. Motor stuck d. Inverter control, the motor long-term operation in low-frequency environment. (Recommended low frequency to 20Hz limit) e. Low temperature environment, the need to replace the low-temperature lubricants 2. Pump outlet no flow: a. Motor does not turn b. Inlet pipe without material or plug c. Inlet and outlet check valve clogging d . Inlet and outlet check valves installed in the wrong direction e. Pump head exhaust is not complete 3. Pump with running noise: a. Worm and worm run normally b. Lube oil filling position is not correct c. Bearing wear d. , The worm meshing gear backlash is too large 4. The impact of noise in the pump body: a. Stroke reversal of the impact of the process of conversion, is a normal phenomenon 5. No change in flow regulation: a. Flow control valve O-ring wear b. Flow Adjust the plunger off the stent c. Pump head exhaust is not complete 6. Pump outlet flow is insufficient: a. Stroke settings are not allowed b. Imported pipe NPSH substandard c. Export pipeline safety valve leak d. Valve wear e. Suction too high 7. Pump body oil level rise, and the oil emulsion: a. Rupture of the diaphragm fluid network in Asia () Editor: Huang Nengwen, QQ:
Neem contact op

Author:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

populaire producten
You may also like
Related Categories

E-mail naar dit bedrijf

Onderwerp:
E-mail:
bericht:

Your message must be betwwen 20-8000 characters

Neem contact op

Author:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

populaire producten

Huis

Product

Whatsapp

Over ons

onderzoek

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

verzenden